Parameter Dictionary Parameters
Bits Description
Battery warning reported by encoder.
Battery error reported by encoder.
Over speed reported by encoder.
Memory error reported by encoder.
STERR reported by encoder.
6 PSERR reported by encoder.
Busy error reported by encoder.
Memory busy reported by encoder.
CRC error on data received from encoder.
Load encoder status. Same as parameter 0x12E, but for the load encoder.
RMS current calculation period. This sets the period over which the RMS current is
calculated. If this value is set to zero, then the RMS current will be updated each time
it is read for the period since the last read. In this case, the RMS current must be
read at least once every 65536 current loop periods (about every 4 seconds) for the
returned RMS values to be accurate. Units: milliseconds.
RMS current over the period set in parameter 0x130. Units: 0.01 A.
Running sum of user current limit in 0.01% units. (i.e., 0 to 10000).
Running sum of amp current limit in 0.01% units. (i.e., 0 to 10000).
Analog output configuration. This parameter sets the mode for the Analog output on
drives so equipped.
Define the mode of the Analog output.
Identify the axis associated with the Analog output.
0 Manual configuration (set using parameter 0x135).
Actual current of configured axis.
Actual velocity of configured axis. The output is a +/- 5V range and is a ratio of the actual
velocity to the velocity loop maximum velocity.
Analog output value. For drives that support an Analog output, this parameter sets