Parameter Dictionary Parameters
active/inactive state of the drive’s general-purpose digital outputs. Each bit
represents an input number. Bit 0 = digital output 0 (OUT0), bit 1 = output 1 (OUT1),
etc., up to output n (OUTn), the number of digital outputs on the drive. Additional bits
are ignored.
Outputs that have been configured for program control can be set by writing to this
parameter. Set a bit to activate the output. It will be activated high or low according to
how it was programmed. Clear a bit to make the output inactive. If an output was not
configured for program control it will not be affected.
Sticky Drive Event Status Register. This read-only parameter is bit-mapped in exactly
the same way as the Drive Event Status Register (0xA0), but instead of giving the
present status of the drive, the sticky version indicates any bits in the event status
that have been set since the last reading of the sticky register.
The sticky register is similar to the Latched Event Status Register (0xA1), but the
latched register must be cleared explicitly, whereas the sticky register is cleared
automatically each time it is read.
or
0x2384:13
Drive Hardware Type. Also known as Product Code. Identifies the specific drive
model. This is an augmented version of Product Family (0x87).
Value Product
XSL: Xenus Panel (obsolete).
0x0203 ACP: Accelnet Panel (obsolete).
XSL-R: Xenus Panel, resolver version.
ACJ: Accelnet Micro Panel.
ACK: Accelnet Micro Module.
0x020E Special.
0x020F Special.
ACJ-S: Accelnet Micro Panel, analog encoder version.
Copley Controls Page 38