Parameter Dictionary Parameters
Trajectory Maximum Acceleration. The trajectory generator will attempt to reach this
acceleration during a move. For s-curve profiles, this value is also used to decelerate
at the end of a move. Units: 10 counts/s
2
.
Trajectory Maximum Deceleration. In trapezoidal trajectory mode, this value will be
used to decelerate at the end of a move. Units: 10 counts/s
2
.
Trajectory Maximum Jerk. Also known as Trajectory Jerk Limit. The S-curve profile
generator uses this value as the jerk (rate of change of acceleration/deceleration)
during moves. Other profiles types do not use jerk limit. Units: 100 counts/s
3
.
Trajectory Abort Deceleration. If a move is aborted, this value will be used by the
trajectory generator to decelerate to a stop. Units: 10 counts/s
2
.
Input 8 Configuration. See Input 0 Configuration (0x78).
Input 9 Configuration. See Input 0 Configuration (0x78).
Input 10 Configuration. See Input 0 Configuration (0x78).
Input 11 Configuration. See Input 0 Configuration (0x78).
Input 12 Configuration. See Input 0 Configuration (0x78).
Input 13 Configuration. See Input 0 Configuration (0x78).
Input 14 Configuration. See Input 0 Configuration (0x78).
Input 15 Configuration. See Input 0 Configuration (0x78).
Regen Resistor Resistance. Units: 0.1 Ω.
Regen Resistor, Continuous Power. Units: W.
Regen Resistor, Peak Power. Units: W.
Regen Resistor, Time At Peak. Units: ms.
Regen Turn On Voltage Units: 0.1 V.
Regen Turn Off Voltage. Units: 0.1 V.
Drive’s Peak Current Rating For Its Internal Regen Transistor. Units: 0.01 A.
Drive's Continuous Current Rating For Its Internal Regen Transistor.
Drive's Time At Peak Current For Its Internal Regen Transistor. Units: ms.
Regen Resistor Model Number String.