Parameter Dictionary Parameters
If clear: programs the drive to abort the current move and remain enabled when a tracking
error occurs.
If set: programs the drive to latch a fault when output current is limited by the I
2
T algorithm.
FPGA failure. This bit is read-only.
Command input lost fault. If set: programs the drive to latch in the disabled state when the
command input is lost.
Unable to initialize internal drive hardware. This bit is read-only.
If set, programs the drive to latch a fault when there is safety circuit consistency check
failure.
If set, programs the drive to latch a fault when the drive is unable to control motor current.
If set, programs the drive to latch a fault when the motor wiring is disconnected (see Open
Motor Wiring Check Current (0x19D).
Digital Input Command Configuration. Defines the configuration of the digital input
commands when the drive is running in a mode that uses them as a control source.
The lower 8 bits control the PWM input configuration for controlling current and
velocity modes. The upper 8 bits configure the digital inputs when running in position
mode.
Bits Description
If set, use PWM in signed/magnitude mode. If clear, use PWM in 50% duty cycle offset
mode.
1 Invert the PWM input if set.
2 Invert the sign input if set.
Allow 100% duty cycle if set. If clear, treat 100% duty cycle as a zero command, providing a
measure of safety in case of controller failure or cable break.
4 If set, use parameter 0xB6 as deadband for PWM input.
If set, allow longer PWM periods (up to 50ms).
For Feature Set C products, setting this bit will cause the Motor Hall Offset (0x4F) to be
added to the angle calculated in UV mode. For Feature Set E products, see UV
Configuration (0x180).
Input pin interpretation for position mode (see below).