Xenus Plus User Guide Specifications
Copley Controls 62
3.7: Analog Inputs
XEL/XPL/XML
Channels
3 (AIN1~IN3)
AIN1~AIN2
AIN3
Type
Differential, non-isolated
Single-ended
Measurement Range
±10 Vdc
0-5 Vdc
Maximum Voltage
Differential
Input to Ground
±10 Vdc
±10 Vdc
±10 Vdc
±10 Vdc
Input Impedance
5 k
4.99 k pull-up to 5V
Resolution
16 Bit
12 Bit
Anti-aliasing filter
14.5 kHz
27 Hz
Scan Time
62.5 s
250 s
Function
Programmable. Current, velocity, or
position command
Motor temperature sensor
XE2/XP2/800-1782/800-1808
Channels
2
AIN1~AIN2
Type
Differential, non-isolated
Measurement Range
±10 Vdc
Maximum VoltageDifferential
Input to Ground
±10 Vdc
±10 Vdc
Input Impedance
5 k
Resolution
14 bit
Anti-aliasing filter
14.5 kHz
Scan Time
62.5 s
Function
Programmable