Xenus PlusTM User Guide P/N 16-01018 Revision 07 August 2014

Pagina 2 - This page for notes

Copley Controls 10 CHAPTER 1: INTRODUCTION This chapter provides an overview of the Copley Controls Xenus Plus drives. Contents include: 1.1: Xenu

Pagina 3 - Copley Controls 3

Xenus Plus User Guide Wiring Copley Controls 100 …Pin Description, continued: 20 +5 Vdc +5 Vdc output. Total load current on J8-20, J10-6, and J1

Pagina 4 - Copley Controls 4

Xenus Plus User Guide Wiring Copley Controls 101 Digital Outputs Wiring Diagram Multi-Mode Port Interface Diagram DriveJ8-16J8-17J8-15TypicalCi

Pagina 5 - ABOUT THIS MANUAL

Xenus Plus User Guide Wiring Copley Controls 102 Analog Input Wiring Diagram Analog Output Wiring Diagram J8-2J8-3J8-15 K37.4 K37.4 K5 KREF

Pagina 6 - Original Instructions

Xenus Plus User Guide Wiring Copley Controls 103 4.10: Secondary I/O 4.10.1: XEL/XPL/XML (J9) Mating Connector Description Manufacturer PN Wire S

Pagina 7 - Document Validity

Xenus Plus User Guide Wiring Copley Controls 104 Optically Isolated Programmable Inputs Wiring Diagram J9J9-2J9-3J9-4J9-5J9-6[COMM_A][IN7]4.99K

Pagina 8 - Product Warnings

Xenus Plus User Guide Wiring Copley Controls 105 Optically Isolated Programmable Outputs Wiring Diagram J9J9-14J9-15J9-12J9-13OUT4 +OUT4 -20O

Pagina 9 - Copley Controls 9

Xenus Plus User Guide Wiring Copley Controls 106 4.10.2: XE2/XP2/800-1782/800-1808 (J12) Mating Connections Description Manufacturer PN Wire Size

Pagina 10 - CHAPTER

Xenus Plus User Guide Wiring Copley Controls 107 …Pin Description, continued: 20 A-MultiEnc /B Programmable differential input/output port. 21 A-

Pagina 11 - Copley Controls 11

Xenus Plus User Guide Wiring Copley Controls 108 Axis B These inputs are for Axis B and are dedicated to specific functions, depending on operati

Pagina 12 - 1.2: CME 2

Xenus Plus User Guide Wiring Copley Controls 109 Analog Input Wiring Diagram Multi-Mode Port Interface Diagram 5 K37.4 K37.4 K5 KREF- (AIN1-

Pagina 13 - 1.6: CPL

Xenus Plus User Guide Introduction Copley Controls 11 1.1: Xenus Plus Family Overview Each Xenus Plus servo drive provides 100% digital control o

Pagina 14

Xenus Plus User Guide Wiring Copley Controls 110 4.10.3: Isolated Control XE2/XP2/800-1808 (J9) J9 is a 26 position male D-sub connector used fo

Pagina 15 - 2.1: Drive Internal Power

Xenus Plus User Guide Wiring Copley Controls 111 …Pin Description, continued: 21 OUT3+ GPI Optically isolated programmable output positive signal

Pagina 16 - Copley Controls 16

Xenus Plus User Guide Wiring Copley Controls 112 Optically Isolated Programmable Inputs Wiring Diagram, XE2/XP2/800-1808 J9J9-6J9-2J9-3J9-4J9-5[

Pagina 17 - 2.4: Feedback

Xenus Plus User Guide Wiring Copley Controls 113 Optically Isolated Programmable Inputs Wiring Diagram, 800-1782 Note: Wiring diagram for IN6 –

Pagina 18 - 2.5: Operating Modes

Xenus Plus User Guide Wiring Copley Controls 114 Optically Isolated Programmable Outputs Wiring Diagram, XE2/XP2/800-1808 Optically Isolated Pro

Pagina 19 - Description

Xenus Plus User Guide Wiring Copley Controls 115 4.11: Motor Feedback The following motor feedback information is true for single and dual axis d

Pagina 20 - Copley Controls 20

Xenus Plus User Guide Wiring Copley Controls 116 Pin Description Quad A/B Incremental Encoder Pin Signal Function 1 Frame Ground Cable shield con

Pagina 21 - Copley Controls 21

Xenus Plus User Guide Wiring Copley Controls 117 Pin Description Resolver Xenus Plus (-R) Pin Signal Function 1 Frame Ground Cable shield connect

Pagina 22 - Accel Limit Decel Limit

Xenus Plus User Guide Wiring Copley Controls 118 …Pin Description, continued: 17 +5 Vdc Encoder +5 Vdc power supply output. Total load current on

Pagina 23

Xenus Plus User Guide Wiring Copley Controls 119 Hall Switch Wiring Diagram In XEL/XPL/XML there are two encoder +5V outputs at 400 mA each, and

Pagina 24 - Copley Controls 24

Xenus Plus User Guide Introduction Copley Controls 12 Model Data Standard Resolver Continuous Current Peak Current Vac XEL-230-18 XML-230-18 XPL

Pagina 25 - 2.6: Input Command Types

Xenus Plus User Guide Wiring Copley Controls 120 Analog Sin/Cos Encoder Wiring Diagram In XEL/XPL/XML there are two encoder +5V outputs at 400 m

Pagina 26 - Copley Controls 26

Xenus Plus User Guide Wiring Copley Controls 121 Resolver Wiring Diagram J10-23J10-22J10-21J10-20J10-1Frame GndResolverCase GroundREF(+)REF(-)CO

Pagina 27 - 2.6.2: PWM Input

Xenus Plus User Guide Wiring Copley Controls 122 Resolver Wiring Diagram, 800-1782 Motor Over Temperature Wiring Diagram: XEL/XPL/XML J10 -7 Dr

Pagina 28 - Direction Input

Xenus Plus User Guide Wiring Copley Controls 123 Motor Over Temperature Wiring Diagram: XE2/XP2/800-1782/800-1808 General Purpose Input Wiring D

Pagina 29 - Down Input

Xenus Plus User Guide Copley Controls 124 APPENDIX A: REGEN RESISTOR SIZING AND CONFIGURATION This chapter describes the steps used to determine

Pagina 30 - 2.7: Communication

Xenus Plus User Guide Regen Resistor Sizing and Configuration Copley Controls 125 A.1: Sizing a Regen Resistor A.1.1: Gather Required Informatio

Pagina 31 - Copley Controls 31

Xenus Plus User Guide Regen Resistor Sizing and Configuration Copley Controls 126 A.1.3: Calculate Energy Returned for Each Deceleration Use the

Pagina 32 - Addressing Method

Xenus Plus User Guide Regen Resistor Sizing and Configuration Copley Controls 127 For mains voltages not listed in the specification table, use t

Pagina 33 - -1 -2 -3

Xenus Plus User Guide Regen Resistor Sizing and Configuration Copley Controls 128 Choose a resistor with a power rating equal to or greater than

Pagina 34 - 2.8: Limit Switches

Xenus Plus User Guide Copley Controls 129 APPENDIX B: I2T TIME LIMIT ALGORITHM The current loop I2T limit specifies the maximum amount of time th

Pagina 35 - 2.9: Brake Operation

Xenus Plus User Guide Introduction Copley Controls 13 1.3: CML/CMO Copley Motion Libraries (CML) and Copley Motion Objects (CMO) make CANopen or

Pagina 36 - 2.10: Status Indicators

Xenus Plus User Guide I2T Time Limit Algorithm Copley Controls 130 B.1: I2T Algorithm B.1.1: I2T Overview The I2T current limit algorithm continu

Pagina 37

Xenus Plus User Guide I2T Time Limit Algorithm Copley Controls 131 B.1.3: I2T Current Limit Algorithm – Application Example I2T Example: Paramete

Pagina 38 - Meaning

Xenus Plus User Guide I2T Time Limit Algorithm Copley Controls 132 I2T Example: Plot Diagrams The plots that follow show the response of a drive

Pagina 39

Copley Controls 133 APPENDIX C: THERMAL CONSIDERATIONS This chapter describes operating temperature characteristics, heatsink options, and heatsink

Pagina 40 - NET-MACRO Network Status

Xenus Plus User Guide Thermal Considerations Copley Controls 134 C.1: Operating Temperature and Cooling Configurations C.1.1: XEL, XPL, and XML M

Pagina 41

Xenus Plus User Guide Thermal Considerations Copley Controls 135 C.1.2: XEL, XPL, and XML Heatsink and Fan Configurations No Heatsink No Fan With

Pagina 42 - XPL J6 STAT Indicator

Xenus Plus User Guide Thermal Considerations Copley Controls 136 C.1.3: XE2, XP2, 800-1782, and 800-1808 Models Thermal and Mounting Configuratio

Pagina 43 - 1 second

Xenus Plus User Guide Thermal Considerations Copley Controls 137 C.2: Heatsink Mounting Instructions (XEL/XPL/XML) A dry film interface pad is us

Pagina 44

Xenus Plus User Guide Thermal Considerations Copley Controls 138 C.3: Heatsink Mounting Instructions (XE2/XP2/800-1782/800-1808) description The

Pagina 45

Copley Controls 139 APPENDIX D: XENUS PLUS FILTER This chapter provides an overview of the Model XTL-FA-01 edge filter. Contents include: D.1: Over

Pagina 46

Copley Controls 14 CHAPTER 2: OPERATIONAL THEORY This chapter describes the basics of Xenus Plus operation. Contents include: 2.1: Drive Internal

Pagina 47 - 2.11: Protection

Xenus Plus User Guide Xenus Plus Filter Copley Controls 140 D.1: Overview The XTL-FA-01 edge filter can be used to minimize noise on the output o

Pagina 48 - Fault is Corrected When…

Xenus Plus User Guide Xenus Plus Filter Copley Controls 141 D.2: XTL-FA-01 Edge Filter Specifications Input Voltage, maximum 373 Vdc Current, max

Pagina 49 - Copley Controls 49

Xenus Plus User Guide Xenus Plus Filter Copley Controls 142 D.4: XTL-FA-01 Edge Filter Dimensions The following diagram shows the mounting dimens

Pagina 50 - Copley Controls 50

Xenus Plus User Guide Xenus Plus Filter Copley Controls 143 D.5: XTL-FA-01 Edge Filter Wiring This section describes the wiring of the XTL-FA-01

Pagina 51 - Copley Controls 51

Xenus Plus User Guide Xenus Plus Filter Copley Controls 144 D.5.2: Connector Locations Edge Filter J1 connects to Xenus Plus J2 (J3 or J4 for XE2

Pagina 52

Xenus Plus User Guide Xenus Plus Filter Copley Controls 145 D.5.3: Cable Notes 1 Keep the Edge Filter to Xenus Plus cable as short as possible.

Pagina 53 - 2.13: Inputs XEL/XPL/XML

Xenus Plus User Guide Xenus Plus Filter Copley Controls 146 D.5.6: Diagram: Edge Filter Wiring with Brushless Motor This is an example for a Xen

Pagina 54 - 2.14.2: Analog Inputs

Copley Controls 147 APPENDIX E: CONNECTING XPL/XP2 FOR SERIAL CONTROL This chapter describes how to connect one or more XPL/XP2 drives for control v

Pagina 55 - 2.15: Outputs, XEL/XPL/XML

Xenus Plus User Guide Connecting XPL/XP2 for Serial Control XPL/XP2 For Serial Control Copley Controls 148 E.1: Single-Axis and Multi-Drop An XPL/X

Pagina 56 - Copley Controls 56

Copley Controls 149 APPENDIX F: ORDERING GUIDE AND ACCESSORIES This chapter lists part numbers for drives and accessories. Contents include: F.1:

Pagina 57 - 2.17: Regen Resistor Theory

Xenus Plus User Guide Operational Theory Copley Controls 15 2.1: Drive Internal Power Power distribution within Xenus Plus is divided into three

Pagina 58

Xenus Plus User Guide Ordering Guide and Accessories Copley Controls 150 F.1: Drive Model Numbers XEL Model Number Description XEL-230-18 Xenus P

Pagina 59 - 3.2: Power Input

Xenus Plus User Guide Ordering Guide and Accessories Copley Controls 151 Drive Model Numbers (cont’d) XPL Model Number Description XPL-230-18 Xen

Pagina 60 - 3.3: Power Output

Xenus Plus User Guide Ordering Guide and Accessories Copley Controls 152 Drive Model Numbers (cont’d) XML Model Number Description XML-230-18 Xen

Pagina 61 - 3.6: Digital Command Input

Xenus Plus User Guide Ordering Guide and Accessories Copley Controls 153 F.2: Accessory Model Numbers Software Model Description CME2 CME 2 Drive

Pagina 62 - 3.7: Analog Inputs

Xenus Plus User Guide Ordering Guide and Accessories Copley Controls 154 CANopen Connector Kit (XPL/XP2) Model Qty Ref Description XPL-NK 1 J7 Su

Pagina 63 - 3.8: Digital Inputs

Xenus Plus User Guide Ordering Guide and Accessories Copley Controls 155 F.4: Regen Resistor Assemblies Model Description XTL-RA-03 Regen Resisto

Pagina 64 - 3.10: Digital Outputs

Xenus Plus User Guide Ordering Guide and Accessories Copley Controls 156 F.7: Copley Standard Regen Resistor Specifications F.7.1: Specifications

Pagina 65 - 3.12: Primary Encoder Inputs

Xenus Plus User Guide P/N 16-01018 Revision 07 August 2014 2011, 2012, 2013, 2014 Copley Controls Analogic Motion Controls 20 Dan Road Canton, MA

Pagina 66 - 3.13: Analog Encoder Inputs

Xenus Plus User Guide Operational Theory Copley Controls 16 2.1.3: Power and Grounding Diagram The graphic below shows the different power secti

Pagina 67 - 3.14: Hall Switch Inputs

Xenus Plus User Guide Operational Theory Copley Controls 17 2.3: Commutation Modes The drive supports three commutation modes to drive brush and

Pagina 68 - 3.15: Resolver Interface

Xenus Plus User Guide Operational Theory Copley Controls 18 2.5: Operating Modes 2.5.1: Modes and Control Loops Nesting of Control Loops and Mod

Pagina 69 - 3.16: Multi-Mode Port

Xenus Plus User Guide Operational Theory Copley Controls 19 2.5.2: Current Mode and Current Loop Current Loop Diagram As shown below, the “front

Pagina 70 - 800-1782

Xenus Plus User Guide This page for notes

Pagina 71 - 3.17: Serial Interface

Xenus Plus User Guide Operational Theory Copley Controls 20 Current Loop Gains The current loop uses these gains: Gain Description Cp - Current

Pagina 72 - 3.18: Network Interfaces

Xenus Plus User Guide Operational Theory Copley Controls 21 2.5.3: Velocity Mode and Velocity Loop Velocity Loop Diagram As shown below, the vel

Pagina 73 - 3.20: Fault Levels

Xenus Plus User Guide Operational Theory Copley Controls 22 Diagram: Effects of Limits on Velocity Command The following diagram illustrates the

Pagina 74 - 3.22: Thermal Impedance

Xenus Plus User Guide Operational Theory Copley Controls 23 2.5.4: Position Mode and Position Loop Position Loop Diagram The drive receives posi

Pagina 75 - XE2/XP2/800-1782/800-1808

Xenus Plus User Guide Operational Theory Copley Controls 24 Position Loop Gains The following gains are used by the position loop to calculate t

Pagina 76 - 3.24: Dimensions

Xenus Plus User Guide Operational Theory Copley Controls 25 2.6: Input Command Types The drive can be controlled by a variety of external source

Pagina 77 - Copley Controls 77

Xenus Plus User Guide Operational Theory Copley Controls 26 Offset To remove the effects of voltage offsets between the controller and the drive

Pagina 78 - 3.24.3: XML Dimensions

Xenus Plus User Guide Operational Theory Copley Controls 27 2.6.2: PWM Input Two Formats The drive can accept a pulse width modulated signal (P

Pagina 79

Xenus Plus User Guide Operational Theory Copley Controls 28 2.6.3: Digital Input Three Formats In position mode, the drive can accept position

Pagina 80 - Copley Controls 80

Xenus Plus User Guide Operational Theory Copley Controls 29 Count Up/Count Down Format In the count up/count down format, one input takes each p

Pagina 81 - Copley Controls 81

Copley Controls 3 TABLE OF CONTENTS About This Manual ...

Pagina 82 - 4.1.3: Connector Locations

Xenus Plus User Guide Operational Theory Copley Controls 30 2.7: Communication As described below, the drive features multiple communication int

Pagina 83 - 1782/800-1808

Xenus Plus User Guide Operational Theory Copley Controls 31 2.7.1: CAN Communication Details (XPL/XP2) CAN Network and CANopen Profiles for Moti

Pagina 84 - Copley Controls 84

Xenus Plus User Guide Operational Theory Copley Controls 32 CANopen Architecture As shown below, in a CANopen motion control system, control loo

Pagina 85 - Copley Controls 85

Xenus Plus User Guide Operational Theory Copley Controls 33 2.7.2: EtherCAT Communication Details (XEL/XE2/800-1782) The XEL/XE2/800-1782 models

Pagina 86 - 4.3: Motor(s)

Xenus Plus User Guide Operational Theory Copley Controls 34 2.8: Limit Switches 2.8.1: Use Digital Inputs to Connect Limit Switches Limit switch

Pagina 87 - 4.4.1: XEL/XPL/XML

Xenus Plus User Guide Operational Theory Copley Controls 35 2.9: Brake Operation 2.9.1: Digital Output Controls Brake Many control systems emp

Pagina 88

Xenus Plus User Guide Operational Theory Copley Controls 36 2.10: Status Indicators 2.10.1: XEL J6 STAT & NET: Drive and EtherCAT State Mach

Pagina 89 - 4.5: Logic Supply / Brake

Xenus Plus User Guide Operational Theory Copley Controls 37 2.10.2: XEL J7: EtherCAT Network Status Indicators XEL J7 Link and Activity Indicat

Pagina 90 - Mating Connector

Xenus Plus User Guide Operational Theory Copley Controls 38 2.10.3: XE2/800-1782 J7 Axis A/B: Drive Status Indicators XE2/800-1782 J7 Axis A/B

Pagina 91 - 4.6: Safe Torque Off

Xenus Plus User Guide Operational Theory Copley Controls 39 2.10.4: XE2/800-1782 J8 RUN, ERR, & L/A Indicators XE2/800-1782 J8 L/A Indicat

Pagina 92 - Copley Controls 92

Xenus Plus User Guide Table of Contents Copley Controls 4 D: Xenus Plus Filter ...

Pagina 93

Xenus Plus User Guide Operational Theory Copley Controls 40 2.10.5: XML J6: Drive and MACRO Network Status Indicators XML J6 STAT Indicator: Dr

Pagina 94 - Copley Controls 94

Xenus Plus User Guide Operational Theory Copley Controls 41 2.10.6: 800-1808 J7: Drive and MACRO Network Status Indicators 800-1808 J7 Axis A/

Pagina 95 - 1 2 3 4 5 6

Xenus Plus User Guide Operational Theory Copley Controls 42 2.10.7: XPL J6 STAT: Drive Status Indicator XPL J6 STAT Indicator XPL Drive status

Pagina 96 - 4.8: Network Ports

Xenus Plus User Guide Operational Theory Copley Controls 43 XPL J6 NET Indicator: CANopen RUN and ERR States The XPL NET indicator color/blink c

Pagina 97 - 4.8.2: CAN Bus (XPL/XP2)

Xenus Plus User Guide Operational Theory Copley Controls 44 2.10.8: XPL J7 Activity/Error: CAN Network Activity and Errors For firmware versions

Pagina 98 - Copley Controls 98

Xenus Plus User Guide Operational Theory Copley Controls 45 2.10.9: XP2 J7 Axis A/B: Drive Status Indicators The LEDs located on connector J7 in

Pagina 99 - 4.9: Control I/O

Xenus Plus User Guide Operational Theory Copley Controls 46 2.10.10: XP2 J8 RUN, ERR, & L/A Indicators XP2 J8 L/A Indicators Shows the stat

Pagina 100

Xenus Plus User Guide Operational Theory Copley Controls 47 2.11: Protection 2.11.1: Safe Torque Off All of the Xenus Plus models provide a Saf

Pagina 101 - Copley Controls 101

Xenus Plus User Guide Operational Theory Copley Controls 48 Clearing Non-Latched Faults The drive clears a non-latched fault, without operator

Pagina 102 - Analog Output Wiring Diagram

Xenus Plus User Guide Operational Theory Copley Controls 49 *Following Error User set following error threshold exceeded. See Position and Velo

Pagina 103 - 4.10: Secondary I/O

Copley Controls 5 ABOUT THIS MANUAL Title, Number, Revision Title The Xenus Plus User Guide Document Number 16-01018 Current Revision 07 Revision H

Pagina 104 - Copley Controls 104

Xenus Plus User Guide Operational Theory Copley Controls 50 2.12: Position and Velocity Errors 2.12.1: Error-Handling Methods In position mode,

Pagina 105 - Copley Controls 105

Xenus Plus User Guide Operational Theory Copley Controls 51 2.12.5: Following Error Fault Details Position Error Reaches Fault Level As describe

Pagina 106 - Pin Description

Xenus Plus User Guide Operational Theory Copley Controls 52 2.12.6: Tracking Window Details Proper Tracking Over Time As described earlier, posi

Pagina 107

Xenus Plus User Guide Operational Theory Copley Controls 53 2.13: Inputs XEL/XPL/XML The Xenus Plus XEL and XPL drives have 15 digital inputs a

Pagina 108

Xenus Plus User Guide Operational Theory Copley Controls 54 2.14: Inputs XE2/XP2/800-1782/800-1808 The XE2, XP2, and 800-1808 drives have 22 dig

Pagina 109

Xenus Plus User Guide Operational Theory Copley Controls 55 2.15: Outputs, XEL/XPL/XML The Xenus Plus XEL and XPL drives have 6 programmable dig

Pagina 110

Xenus Plus User Guide Operational Theory Copley Controls 56 2.16: Outputs, XE2/XP2/800-1782/800-1808 XE2/XP2/800-1808 has 7 programmable digita

Pagina 111 - 800-1782 Pin Description

Xenus Plus User Guide Operational Theory Copley Controls 57 2.17: Regen Resistor Theory 2.17.1: Regeneration When a load is accelerated, electri

Pagina 112 - Copley Controls 112

Copley Controls 58 CHAPTER 3: SPECIFICATIONS This chapter describes the drive specifications. Contents include: 3.1: Agency Approvals ...

Pagina 113 - Copley Controls 113

Xenus Plus User Guide Specifications Copley Controls 59 3.1: Agency Approvals CE Compliant UL Compliant RoHS Compliant Standard XEL/XPL/X

Pagina 114

Xenus Plus User Guide About this Manual Copley Controls 6 EC Declaration of Conformity - Contents The complete EC Declarations of Conformity for

Pagina 115 - 4.11: Motor Feedback

Xenus Plus User Guide Specifications Copley Controls 60 3.3: Power Output Model XEL-230-18 (-R) XPL-230-18 (-R) XML-230-18 (-R) XEL-230-36 (-R)

Pagina 116

Xenus Plus User Guide Specifications Copley Controls 61 3.4: Control Loops Type Current Velocity Position 100% digital. Sampling rate (time) C

Pagina 117 - Pin Description 800-1782

Xenus Plus User Guide Specifications Copley Controls 62 3.7: Analog Inputs XEL/XPL/XML Channels 3 (AIN1~IN3) AIN1~AIN2 AIN3 Type Differential,

Pagina 118

Xenus Plus User Guide Specifications Copley Controls 63 3.8: Digital Inputs XEL/XPL/XML Channels 15 (IN1~IN15) IN1~IN2, IN15 IN3~IN6 IN7~IN14 T

Pagina 119 - Hall Switch Wiring Diagram

Xenus Plus User Guide Specifications Copley Controls 64 3.9: Analog Outputs XEL/XPL/XML Channels 1 Type Single-ended Range 0-5 Vdc Resolution 1

Pagina 120 - Copley Controls 120

Xenus Plus User Guide Specifications Copley Controls 65 3.11: Encoder Power Supply Output XEL/XPL/XML Number 2 Voltage Output +5 Vdc ±2% Maximu

Pagina 121 - Resolver Wiring Diagram

Xenus Plus User Guide Specifications Copley Controls 66 3.13: Analog Encoder Inputs XEL/XPL/XML Channels 2 Type Differential, non-isolated Signa

Pagina 122

Xenus Plus User Guide Specifications Copley Controls 67 3.14: Hall Switch Inputs XEL/XPL/XML Channels 3 (U, V and W) Type 74HC14 Schmitt trigger

Pagina 123

Xenus Plus User Guide Specifications Copley Controls 68 3.15: Resolver Interface XEL/XPL/XML Channels 3 Type Transmit, 1:1 to 2:1 transformatio

Pagina 124 - APPENDIX

Xenus Plus User Guide Specifications Copley Controls 69 3.16: Multi-Mode Port XEL/XPL/XML Channels 4 Type Bi-Directional, Differential RS-422.

Pagina 125

Xenus Plus User Guide About this Manual Copley Controls 7 Related Documentation For important setup and operation information, see the CME 2 User

Pagina 126

Xenus Plus User Guide Specifications Copley Controls 70 800-1782 Channels 6 Type Differential RS-422. Non-isolated Signals A, /A, B, /B, X, /X

Pagina 127 - Capacity

Xenus Plus User Guide Specifications Copley Controls 71 3.17: Serial Interface XEL/XPL/XML Channels 1 Type RS-232, DTE Signals Rxd, Txd, Gnd Ba

Pagina 128 - A.1.11: Select Fuses

Xenus Plus User Guide Specifications Copley Controls 72 3.18: Network Interfaces Model XEL/XE2/800-1782 XPL/XP2 XML/800-1808 Channels 1 Connecto

Pagina 129

Xenus Plus User Guide Specifications Copley Controls 73 3.19: Status Indicators Model XEL XPL XML LED: Network Status STAT Bicolor LED, status

Pagina 130 - T Algorithm

Xenus Plus User Guide Specifications Copley Controls 74 3.21: Power Dissipation Model: XEL-230-18 (-R) XPL-230-18 (-R) XML-230-18 (-R) XEL-230-3

Pagina 131 - B.1.3: I

Xenus Plus User Guide Specifications Copley Controls 75 3.23: Mechanical and Environmental XEL/XPL/XML Size 7.92 in (201,2 mm) X 5.51 in (139,9

Pagina 132 - T current limit

Xenus Plus User Guide Specifications Copley Controls 76 3.24: Dimensions 3.24.1: XEL/XPL Dimensions

Pagina 133

Xenus Plus User Guide Specifications Copley Controls 77 3.24.2: XE2/XP2/800-1782/800-1808 Dimensions

Pagina 134 - Ambient Temperature (

Xenus Plus User Guide Specifications Copley Controls 78 3.24.3: XML Dimensions

Pagina 135 - 4.25 in

Xenus Plus User Guide Copley Controls 79 CHAPTER 4: WIRING This chapter describes the wiring of drive and motor connections. Contents include: 4

Pagina 136 - Configurations

Xenus Plus User Guide About this Manual Copley Controls 8 Product Warnings Observe all relevant state, regional and local safety regulations when

Pagina 137

Xenus Plus User Guide Wiring Copley Controls 80 4.1: General Wiring Instructions 4.1.1: Electrical Codes and Warnings Be sure that all wiring com

Pagina 138 - 1782/800-1808)

Xenus Plus User Guide Wiring Copley Controls 81 4.1.2: Grounding Considerations Primary Grounding Functions A grounding system has three primary

Pagina 139

Xenus Plus User Guide Wiring Copley Controls 82 4.1.3: Connector Locations Connector locations for XEL, XPL and XML (J1-J10), are shown below. X

Pagina 140 - D.1: Overview

Xenus Plus User Guide Wiring Copley Controls 83 4.2: AC Mains (J1) XEL/XPL/XML/XE2/XP2/800-1782/800-1808 The Mains connector information below is

Pagina 141 - D.3: Thermal Considerations

Xenus Plus User Guide Wiring Copley Controls 84 AC Mains Wiring Diagram (Single-Phase) XEL/XPL/XML AC Mains Wiring Diagram (Three-Phase) XEL/

Pagina 142 - Copley Controls 142

Xenus Plus User Guide Wiring Copley Controls 85 AC Mains Wiring Diagram (Single-Phase) XE2/XP2/800-1782/800-1808 AC Mains Wiring Diagram (Three

Pagina 143 - Copley Controls 143

Xenus Plus User Guide Wiring Copley Controls 86 4.3: Motor(s) Mating Connector Description Euro-style, 4 position, 5.0 mm pluggable female termin

Pagina 144 - D.5.2: Connector Locations

Xenus Plus User Guide Wiring Copley Controls 87 4.4: Regen Resistor (Optional) 4.4.1: XEL/XPL/XML Mating Connector Description Euro-style, 5 posi

Pagina 145 - D.5.3: Cable Notes

Xenus Plus User Guide Wiring Copley Controls 88 4.4.2: XE2/XP2/800-1782/800-1808 Mating Connector Description Euro-style, 3 position, 5.0 mm plug

Pagina 146

Xenus Plus User Guide Wiring Copley Controls 89 4.5: Logic Supply / Brake 4.5.1: XEL/XPL/XML (J4) The following information is for XEL/XPL/XML dr

Pagina 147

Xenus Plus User Guide About this Manual Copley Controls 9 This page for notes.

Pagina 148 - Copley Controls 148

Xenus Plus User Guide Wiring Copley Controls 90 4.5.2: XE2/XP2/800-1782/800-1808 (J5) The following information is for XE2/XP2/800-1782/800-1808

Pagina 149

Xenus Plus User Guide Wiring Copley Controls 91 4.6: Safe Torque Off 4.6.1: XEL/XPL/XML (J5) The following information is for XEL and XPL drives

Pagina 150 - F.1: Drive Model Numbers

Xenus Plus User Guide Wiring Copley Controls 92 Safe Torque Off Wiring Diagram (XEL/XPL/XML) NOTE: The diagram below includes the STO bypass conn

Pagina 151

Xenus Plus User Guide Wiring Copley Controls 93 4.6.2: XE2/XP2/800-1782/800-1808 (J6) The following information is for XE2, XP2, 800-1782, and 80

Pagina 152 - 800-1808

Xenus Plus User Guide Wiring Copley Controls 94 Safe Torque Off Bypass Wiring Diagram (XE2/XP2/800-1782/800-1808) The diagram below includes the

Pagina 153 - F.2: Accessory Model Numbers

Xenus Plus User Guide Wiring Copley Controls 95 4.7: RS-232 Serial Communications Mating Connector 6-position, modular connector (RJ-11 style). C

Pagina 154 - F.3: Heatsink Kits

Xenus Plus User Guide Wiring Copley Controls 96 4.8: Network Ports 4.8.1: EtherCAT (XEL/XE2/800-1782) Mating Connector Dual RJ-45 sockets accept

Pagina 155 - F.6: Order Example

Xenus Plus User Guide Wiring Copley Controls 97 4.8.2: CAN Bus (XPL/XP2) Mating Connector 8-position, modular connector (RJ-45 style). Copley Con

Pagina 156 - F.7.2: Dimensions

Xenus Plus User Guide Wiring Copley Controls 98 4.8.3: MACRO Port (J7-XML/J8-800-1808) The XML/800-1808’s duplex SC sockets, shown below, accept

Pagina 157

Xenus Plus User Guide Wiring Copley Controls 99 4.9: Control I/O 4.9.1: XEL/XPL/XML (J8) Mating Connectors Description Manufacturer PN Wire Size