CME 2 User Guide Control Loops
Copley Controls 115
11.2: Current Loop Auto Tune
Tune the Current Loop with Auto Tune
METHOD: The current loop Auto Tune algorithm applies a square-wave command to the
current loop and adjusts current loop proportional gain (Cp) and current loop integral
gain (Ci) until a desirable waveform is obtained.
Initial current loop proportional gain (Cp) and current loop integral gain (Ci) values can
be calculated with The Calculate Function (p. 54).
1
Click I Loop to open the Current Loop screen:
2
Verify that the amplifier is hardware enabled.
3
Click Auto Tune to open screen and start the Current Loop Auto Tune.
4
To Change the Auto Tune Current, Press Stop, enter the new current in the Auto Tune
Current field, and then press Start.